Heath-zenith Instant Motion Sensor Light Control SL-5211 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Sécurité Heath-zenith Instant Motion Sensor Light Control SL-5211. Heath Zenith Instant Motion Sensor Light Control SL-5211 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 8
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Mode: On-Time: Works: Day Night
Test 5 Sec x x
Auto 1, 5 or 10 min x
Manual Until Dawn* x
© 2007 HeathCo LLC 595-4238-07
Features
Turns on lighting when motion is detected.
Automatically turns lighting off.
Photocell keeps the lighting off during daylight hours.
Requirements
The Light Control requires 120-volts AC.
If you want to use Manual Override, the control must be
wired through a switch.
Some codes require installation by a qualified elec-
trician.
OPERATION
Instant Motion Sensor
Light Control
Model SL-5211
Parts
The SL-5211 package includes:
The Sensor and Lamp Module
Two mounting screws
Lamp
Module
Existing Light
Fixture
Sensor
Module
Sensor
Cord
Typical Installation
The lamp module is not weather tight. It should only be
used inside of a light fixture.
10 5 1 TEST
ON-TIME
TEST
* resets to Auto Mode at dawn.
ON-TIME
AUTO
10 5 1 TEST
MANUAL MODE
... back on.
1 Second OFF
then...
Mode Switching Summary
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn the power
off for one minute, then back on. After the calibration time
the control will be in the AUTO mode.
Move ON-TIME Switch to
1, 5, or 10 minutes
Flip light switch off
for one second then
back on*
Note: When first turned on wait about 1
1
/
2
minutes for the
circuitry to calibrate.
Put the ON-TIME switch on the bottom of
the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5, or 10
minute position.
Manual mode only works at night be-
cause daylight returns the sensor to
AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the ON-
TIME switch in the 1, 5, or 10 position.
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - Light Control

Mode: On-Time: Works: Day NightTest 5 Sec x xAuto 1, 5 or 10 min xManual Until Dawn* x© 2007 HeathCo LLC 595-4238-07Features• Turns on lighting when m

Page 2 - INSTALLATION

2595-4238-07INSTALLATION.❒ Before proceeding with the installation, TURN OFFTHE POWER TO THE LIGHTING CIRCUIT AT THECIRCUIT BREAKER OR FUSE BOX to avo

Page 3 - SPECIFICATIONS

3595-4238-07TEST AND ADJUSTMENT❒ Turn on the circuit breaker and light switch.SPECIFICATIONSRange . . . . . . . . . . . . Up to 60 feet (varies with s

Page 4 - TECHNICAL SERVICE

4595-4238-07POSSIBLE CAUSE1. A sensor is positioned too close to the lamp orpointed at nearby objects that cause heat totrigger the sensor. (Repositio

Page 5 - DECORATIVO SENSOR

5595-4238-07Modalidad: A tiempo: Trabaja: Día NochePrueba 5 seg. x xAutom. 1, 5 ó 10 min. xManual Hasta el amanecer* xCaracterísticas• Prende la luz c

Page 6 - INSTALACION

6595-4238-07Bucle CaídoIMPORTANTE: Si el cable del detector sale por la partesuperior de la instalación fija, asegúrese de que la instalaciónse cierr

Page 7 - ESPECIFICACIONES

7595-4238-07Apunte el detectormás arriba paramayor coberturaApunte el detectorhacia abajo parapoca coberturaDetectorMovimientoMovimientoLo menos sensi

Page 8 - SERVICIO TÉCNICO

8595-4238-07SINTOMALa luz seprendedurante el día.La luz seprende sinninguna razónaparente.La luz seprende y seapaga.POSIBLE CAUSA1. El Control de Luz

Commentaires sur ces manuels

Pas de commentaire